id | field name | definition |
0 | sph_descriptor_title |
ascii string | size: 15 |
Sph_Descriptor=
fixed value: "Sph_Descriptor="
|
hidden: true
|
1 | quote_1 |
ascii char | size: 1 |
quotation mark
fixed value: "\""
|
hidden: true
|
2 | sph_descriptor |
ascii string | size: 28 |
SPH descriptor: ASCII string describing the product
|
|
3 | quote_2 |
ascii char | size: 1 |
quotation mark
fixed value: "\""
|
hidden: true
|
4 | newline_char_1 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
5 | spare_1 |
ascii string | size: 40 |
Spare
|
hidden: true
|
6 | newline_char_2 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
7 | ref_rbc_suite_title |
ascii string | size: 14 |
Ref_RBC_Suite=
fixed value: "Ref_RBC_Suite="
|
hidden: true
|
8 | quote_3 |
ascii char | size: 1 |
quotation mark
fixed value: "\""
|
hidden: true
|
9 | ref_rbc_suite |
ascii string | size: 20 |
Reference of the processing suite that was used to produce the Rayleigh Brillouin lookup tables
|
|
10 | quote_4 |
ascii char | size: 1 |
quotation mark
fixed value: "\""
|
hidden: true
|
11 | newline_char_3 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
12 | num_p_title |
ascii string | size: 6 |
Num_P=
fixed value: "Num_P="
|
hidden: true
|
13 | num_p |
ascii int16 | size: 6 |
Number of pressure bins in P_Grid (typical value: 23)
|
|
14 | newline_char_4 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
15 | num_t_title |
ascii string | size: 6 |
Num_T=
fixed value: "Num_T="
|
hidden: true
|
16 | num_t |
ascii int16 | size: 6 |
Number of temperature bins in T_Grid (typical value: 161)
|
|
17 | newline_char_5 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
18 | num_f_title |
ascii string | size: 6 |
Num_F=
fixed value: "Num_F="
|
hidden: true
|
19 | num_f |
ascii int16 | size: 6 |
Number of frequency bins in F_Gridtmp (typical value: 937)
|
|
20 | newline_char_6 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
21 | num_fp_title |
ascii string | size: 7 |
Num_FP=
fixed value: "Num_FP="
|
hidden: true
|
22 | num_fp |
ascii int16 | size: 6 |
Number of frequency bins in F_FP. This number is also the size of the arrays TA_FP and TB_FP. (Typical value: 877)
|
|
23 | newline_char_7 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
24 | num_fd_title |
ascii string | size: 7 |
Num_Fd=
fixed value: "Num_Fd="
|
hidden: true
|
25 | num_fd |
ascii int16 | size: 6 |
Number of frequency bins in Fd (typical value: 61)
|
|
26 | newline_char_8 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
27 | num_rr_title |
ascii string | size: 7 |
Num_RR=
fixed value: "Num_RR="
|
hidden: true
|
28 | num_rr |
ascii int16 | size: 6 |
Number of responses in RR (typical value: 101)
|
|
29 | newline_char_9 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
30 | spare_2 |
ascii string | size: 40 |
Spare
|
hidden: true
|
31 | newline_char_10 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
32 | p_min_title |
ascii string | size: 6 |
P_min=
fixed value: "P_min="
|
hidden: true
|
33 | p_min |
ascii uint32 | size: 11 |
Minimum pressure considered in the RBC calculations
unit: "Pa"
|
|
34 | p_min_units |
ascii string | size: 4 |
fixed value: "<Pa>"
|
hidden: true
|
35 | newline_char_11 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
36 | p_max_title |
ascii string | size: 6 |
P_max=
fixed value: "P_max="
|
hidden: true
|
37 | p_max |
ascii uint32 | size: 11 |
Minimum pressure considered in the RBC calculations
unit: "Pa"
|
|
38 | p_max_units |
ascii string | size: 4 |
fixed value: "<Pa>"
|
hidden: true
|
39 | newline_char_12 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
40 | t_min_title |
ascii string | size: 6 |
T_min=
fixed value: "T_min="
|
hidden: true
|
41 | t_min |
ascii uint16 (double) | size: 6 |
Minimum temperature considered in the RBC calculations
unit: "1e-2 K"
converted unit: "K" (multiply by 1/100)
|
|
42 | t_min_units |
ascii string | size: 7 |
fixed value: "<10-2K>"
|
hidden: true
|
43 | newline_char_13 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
44 | t_max_title |
ascii string | size: 6 |
T_max=
fixed value: "T_max="
|
hidden: true
|
45 | t_max |
ascii uint16 (double) | size: 6 |
Maximum temperature considered in the RBC calculations
unit: "1e-2 K"
converted unit: "K" (multiply by 1/100)
|
|
46 | t_max_units |
ascii string | size: 7 |
fixed value: "<10-2K>"
|
hidden: true
|
47 | newline_char_14 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
48 | laser_freq_offset_start_title |
ascii string | size: 24 |
Laser_Freq_Offset_Start=
fixed value: "Laser_Freq_Offset_Start="
|
hidden: true
|
49 | laser_freq_offset_start |
ascii double | size: 13 |
First offset of the laser frequency in the Fabry-Perot transfer function file
unit: "MHz"
|
|
50 | laser_freq_offset_start_units |
ascii string | size: 5 |
fixed value: "<MHz>"
|
hidden: true
|
51 | newline_char_15 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
52 | laser_freq_offset_stop_title |
ascii string | size: 23 |
Laser_Freq_Offset_Stop=
fixed value: "Laser_Freq_Offset_Stop="
|
hidden: true
|
53 | laser_freq_offset_stop |
ascii double | size: 13 |
Last offset of the laser frequency in the Fabry-Perot transfer function file
unit: "MHz"
|
|
54 | laser_freq_offset_stop_units |
ascii string | size: 5 |
fixed value: "<MHz>"
|
hidden: true
|
55 | newline_char_16 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
56 | total_num_of_observations_title |
ascii string | size: 26 |
Total_Num_of_Observations=
fixed value: "Total_Num_of_Observations="
|
hidden: true
|
57 | total_num_of_observations |
ascii int32 | size: 11 |
Total number of observations used in the Fabry-Perot transfer function file
|
|
58 | newline_char_17 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
59 | total_num_of_measurements_title |
ascii string | size: 26 |
Total_Num_of_Measurements=
fixed value: "Total_Num_of_Measurements="
|
hidden: true
|
60 | total_num_of_measurements |
ascii int32 | size: 11 |
Total number of measurements used in the Fabry-Perot transfer function file
|
|
61 | newline_char_18 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
62 | total_num_of_reference_pulses_title |
ascii string | size: 30 |
Total_Num_of_Reference_Pulses=
fixed value: "Total_Num_of_Reference_Pulses="
|
hidden: true
|
63 | total_num_of_reference_pulses |
ascii int32 | size: 11 |
Total number of reference pulses used in the Fabry-Perot transfer function file
|
|
64 | newline_char_19 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
65 | total_num_of_corrupt_mie_meas_title |
ascii string | size: 30 |
Total_Num_of_Corrupt_Mie_Meas=
fixed value: "Total_Num_of_Corrupt_Mie_Meas="
|
hidden: true
|
66 | total_num_of_corrupt_mie_meas |
ascii int32 | size: 11 |
Total number of corrupted Mie measurements in the Fabry-Perot transfer function file
|
|
67 | newline_char_20 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
68 | total_num_of_corrupt_ray_meas_title |
ascii string | size: 30 |
Total_Num_of_Corrupt_Ray_Meas=
fixed value: "Total_Num_of_Corrupt_Ray_Meas="
|
hidden: true
|
69 | total_num_of_corrupt_ray_meas |
ascii int32 | size: 11 |
Total number of corrupted Rayleigh measurements in the Fabry-Perot transfer function file
|
|
70 | newline_char_21 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
71 | total_num_of_corrupt_mie_refp_title |
ascii string | size: 30 |
Total_Num_of_Corrupt_Mie_RefP=
fixed value: "Total_Num_of_Corrupt_Mie_RefP="
|
hidden: true
|
72 | total_num_of_corrupt_mie_refp |
ascii int32 | size: 11 |
Total number of corrupted Mie reference pulses in the Fabry-Perot transfer function file
|
|
73 | newline_char_22 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
74 | total_num_of_corrupt_ray_refp_title |
ascii string | size: 30 |
Total_Num_of_Corrupt_Ray_RefP=
fixed value: "Total_Num_of_Corrupt_Ray_RefP="
|
hidden: true
|
75 | total_num_of_corrupt_ray_refp |
ascii int32 | size: 11 |
Total number of corrupted Rayleigh reference pulses in the Fabry-Perot transfer function file
|
|
76 | newline_char_23 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
77 | average_error_fp_response_a_title |
ascii string | size: 28 |
Average_Error_FP_Response_A=
fixed value: "Average_Error_FP_Response_A="
|
hidden: true
|
78 | average_error_fp_response_a |
ascii double | size: 11 |
Average error in Fabry-Perot response in the transfer function file, for channel A
|
|
79 | newline_char_24 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
80 | average_error_fp_response_b_title |
ascii string | size: 28 |
Average_Error_FP_Response_B=
fixed value: "Average_Error_FP_Response_B="
|
hidden: true
|
81 | average_error_fp_response_b |
ascii double | size: 11 |
Average error in Fabry-Perot response in the transfer function file, for channel B
|
|
82 | newline_char_25 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|
83 | spare_3 |
ascii string | size: 40 |
Spare
|
hidden: true
|
84 | newline_char_26 |
ascii char | size: 1 |
newline
fixed value: "\n"
|
hidden: true
|