Auxiliary_Calibration_LCP_03_05

xml record "Auxiliary_Calibration_LCP_03_05"
Auxiliary Calibration LCP

idfield namedefinition
0List_of_Data_Set_Records
xml record
List of Data Set Records

attribute: count
xml string


idfield namedefinition
0Data_Set_Record
xml array[dim_0]
dim_0: determined automatically from xml file
xml record
Data Set Record

idfield namedefinition
0First_Start_of_Observation_Time
ascii timesize: 23
Start of observation time of the first BRC

unit: "s since 2000-01-01"

value: if(str(., 23) == "UTC=9999-99-99T99:99:99", +inf, if(str(., 23) == "UTC=0000-00-00T00:00:00", -inf, time(str(.), "'UTC='yyyy-MM-dd'T'HH:mm:ss|'TAI='yyyy-MM-dd'T'HH:mm:ss|'GPS='yyyy-MM-dd'T'HH:mm:ss|'UT1='yyyy-MM-dd'T'HH:mm:ss")))
ascii stringsize: 23
CCSDS ASCII datetime with time reference "RRR=YYYY-MM-DDThh:mm:ss". The reference RRR can be any of "UT1", "UTC", "TAI", or "GPS".
1Last_Start_of_Observation_Time
ascii timesize: 23
Start of observation time of the last BRC

unit: "s since 2000-01-01"

value: if(str(., 23) == "UTC=9999-99-99T99:99:99", +inf, if(str(., 23) == "UTC=0000-00-00T00:00:00", -inf, time(str(.), "'UTC='yyyy-MM-dd'T'HH:mm:ss|'TAI='yyyy-MM-dd'T'HH:mm:ss|'GPS='yyyy-MM-dd'T'HH:mm:ss|'UT1='yyyy-MM-dd'T'HH:mm:ss")))
ascii stringsize: 23
CCSDS ASCII datetime with time reference "RRR=YYYY-MM-DDThh:mm:ss". The reference RRR can be any of "UT1", "UTC", "TAI", or "GPS".
2List_of_LCP_Results
xml record
List of LCP result per phase value

attribute: count
xml string


idfield namedefinition
0LCP_Result
xml array[dim_0]
dim_0: determined automatically from xml file
xml record
LCP Result

idfield namedefinition
0Laser_Chopper_Phase_Delay
ascii double
Laser chopper phase delay

attribute: unit
ascii stringsize: 3
fixed value: "TMC"

available: optional
1Mie_Maximum_Flux
ascii double
Mie Maximum Flux

attribute: unit
ascii stringsize: 10
fixed value: "PixelLevel"

available: optional
2Mie_Mean_Background
ascii double
Mie Mean Background

attribute: unit
ascii stringsize: 10
fixed value: "PixelLevel"

available: optional
3Mie_Mean_Flux
ascii double
Mie Mean Flux

attribute: unit
ascii stringsize: 10
fixed value: "PixelLevel"

available: optional
4Mie_Reference_Pulse_Maximum_Flux
ascii double
Mie Maximum Flux

attribute: unit
ascii stringsize: 10
fixed value: "PixelLevel"

available: optional
5Mie_Reference_Pulse_Mean_Background
ascii double
Mie Mean Background

attribute: unit
ascii stringsize: 10
fixed value: "PixelLevel"

available: optional
6Mie_Reference_Pulse_Mean_Flux
ascii double
Mie Mean Flux

attribute: unit
ascii stringsize: 10
fixed value: "PixelLevel"

available: optional
7Rayleigh_Maximum_Flux
ascii double
Rayleigh Reference Pulse Maximum Flux

attribute: unit
ascii stringsize: 10
fixed value: "PixelLevel"

available: optional
8Rayleigh_Mean_Background
ascii double
Rayleigh Reference Pulse Mean Background

attribute: unit
ascii stringsize: 10
fixed value: "PixelLevel"

available: optional
9Rayleigh_Mean_Flux
ascii double
Rayleigh Reference Pulse Mean Flux

attribute: unit
ascii stringsize: 10
fixed value: "PixelLevel"

available: optional
10Rayleigh_Reference_Pulse_Maximum_Flux
ascii double
Rayleigh Maximum Flux

attribute: unit
ascii stringsize: 10
fixed value: "PixelLevel"

available: optional
11Rayleigh_Reference_Pulse_Mean_Background
ascii double
Rayleigh Mean Background

attribute: unit
ascii stringsize: 10
fixed value: "PixelLevel"

available: optional
12Rayleigh_Reference_Pulse_Mean_Flux
ascii double
Rayleigh Mean Flux

attribute: unit
ascii stringsize: 10
fixed value: "PixelLevel"

available: optional
13Phase_Step_Data_Statistics
xml record
Data statistics for the phase step

idfield namedefinition
0Num_Mie_Observations_Used
ascii int32
Number of Mie observations used when there are usuable Mie measuremtns and reference pulses
1Num_Rayleigh_Observations_Used
ascii int32
Number of Rayleigh observations used when there are usuable Rayleigh measuremtns and pulses
2Num_Mie_Measurements_Usable
ascii int32
Number of Mie measurements usable. The measurement is usable if the laser transmitter frequency is locked; and Mie measurement is not corrupted
3Num_Rayleigh_Measurements_Usable
ascii int32
Number of Rayleigh measurements usable. The measurement is usable if the laser transmitter frequency is locked;and Rayleigh measurement is not corrupted
4Num_Mie_Reference_Pulses_Usable
ascii int32
Number of Mie reference pulses usable. The pulse is usable if the laser transmitter frequency is locked; and Mie reference pulse is not corrupted
5Num_Rayleigh_Reference_Pulses_Usable
ascii int32
Number of Rayleigh reference pulses usable. The pulse is usable if the laser transmitter frequency is locked; and Rayleigh reference pulse is not corrupted
6Num_Measurement_Laser_Freq_Unlocked
ascii int32
Total number of measurements with laser transmitter frequency unlocked status
7Num_Reference_Pulse_Laser_Freq_Unlocked
ascii int32
Total number of reference pulses with laser transmitter frequency unlocked status
8Num_Corrupt_Mie_Measurements
ascii int32
Total number of corrupt Mie measurements
9Num_Corrupt_Rayleigh_Measurements
ascii int32
Total number of corrupt Rayleigh measurements
10Num_Corrupt_Mie_Reference_Pulses
ascii int32
Total number of corrupt Mie reference pulses
11Num_Corrupt_Rayleigh_Reference_Pulses
ascii int32
Total number of corrupt Rayleigh reference pulses