| id | field name | definition |
| 0 | Laser_Chopper_Phase_Delay |
| ascii double |
Laser chopper phase delay
| attribute: unit |
| ascii string | size: 3 |
|
fixed value: "TMC"
|
available: optional
|
|
|
| 1 | Mie_Maximum_Flux |
| ascii double |
Mie maximum flux: maximum column value of array of mean over all Mie measurments and atmospheric height bins
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 2 | Mie_Mean_Background |
| ascii double |
Mie mean background: mean value of first and last value of array of mean over all Mie measurements and atmospheric height bins.
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 3 | Mie_Mean_Flux |
| ascii double |
Mie mean flux: mean value of array of mean over all Mie measurements and atmospheric height bins of all 16 usable ACCD columns
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 4 | Mie_Mean_Flux_Lowest_Col |
| ascii double |
First value of array of mean over all Mie measurements and atmospheric height bins of 16 usable ACCD columns
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 5 | Mie_Mean_Flux_Highest_Col |
| ascii double |
Last value of array of mean over all Mie measurements and atmospheric height bins of 16 usable ACCD columns
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 6 | Mie_Reference_Pulse_Maximum_Flux |
| ascii double |
Mie maximum reference pulse flux: maximum column value of mean reference pulse array of phase step
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 7 | Mie_Reference_Pulse_Mean_Background |
| ascii double |
Mie mean reference pulse background: mean value of first and last useful pixel of mean reference pulse array of phase step
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 8 | Mie_Reference_Pulse_Mean_Flux |
| ascii double |
Mie mean reference pulse flux: mean value of all 16 usable ACCD columns of mean reference pulse array
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 9 | Mie_Reference_Pulse_Mean_Flux_Lowest_Col |
| ascii double |
Mie mean reference pulse flux:value of first of 16 usable ACCD columns of mean reference pulse
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 10 | Mie_Reference_Pulse_Mean_Flux_Highest_Col |
| ascii double |
Mie mean reference pulse flux: value of last of 16 usable ACCD columns of mean reference pulse
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 11 | Rayleigh_Maximum_Flux |
| ascii double |
Rayleigh maximum flux: mean value of first and last value of array of mean over all Rayleigh measurements and atmospheric height bins.
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 12 | Rayleigh_Mean_Background |
| ascii double |
Rayleigh mean background: mean value of first and last value of array of mean over all Rayleigh measurements and atmospheric height bins.
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 13 | Rayleigh_Mean_Flux_Channel_A |
| ascii double |
Rayleigh mean flux: mean value of array of mean over all Rayleigh measurements and atmospheric height bins of 8 ACCD columns of channel A
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 14 | Rayleigh_Mean_Flux_Channel_B |
| ascii double |
Rayleigh mean flux: mean value of array of mean over all Rayleigh measurements and atmospheric height bins of 8 ACCD columns of channel B
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 15 | Rayleigh_Reference_Pulse_Maximum_Flux |
| ascii double |
Rayleigh reference pulse maximum flux:: maximum column value of mean reference pulse array of phase step
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 16 | Rayleigh_Reference_Pulse_Mean_Background |
| ascii double |
Rayleigh reference pulse mean background: mean value of first and last useful pixel of mean reference pulse array of phase step
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 17 | Rayleigh_Reference_Pulse_Mean_Flux_Channel_A |
| ascii double |
Rayleigh reference pulse mean flux:mean value of 8 ACCD columns of channel A mean reference pulse
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 18 | Rayleigh_Reference_Pulse_Mean_Flux_Channel_B |
| ascii double |
Rayleigh reference pulse mean flux:mean value of 8 ACCD columns of channel B mean reference pulse
| attribute: unit |
| ascii string | size: 11 |
|
fixed value: "ACCD counts"
|
available: optional
|
|
|
| 19 | Phase_Step_Data_Statistics |
| xml record |
Data statistics for the phase step
| id | field name | definition |
| 0 | Num_Mie_Observations_Used |
| ascii int32 |
|
Number of Mie observations used when there are usuable Mie measuremtns and reference pulses
|
|
| 1 | Num_Rayleigh_Observations_Used |
| ascii int32 |
|
Number of Rayleigh observations used when there are usuable Rayleigh measuremtns and pulses
|
|
| 2 | Num_Mie_Measurements_Usable |
| ascii int32 |
|
Number of Mie measurements usable. The measurement is usable if the laser transmitter frequency is locked; and Mie measurement is not corrupted
|
|
| 3 | Num_Rayleigh_Measurements_Usable |
| ascii int32 |
|
Number of Rayleigh measurements usable. The measurement is usable if the laser transmitter frequency is locked;and Rayleigh measurement is not corrupted
|
|
| 4 | Num_Mie_Reference_Pulses_Usable |
| ascii int32 |
|
Number of Mie reference pulses usable. The pulse is usable if the laser transmitter frequency is locked; and Mie reference pulse is not corrupted
|
|
| 5 | Num_Rayleigh_Reference_Pulses_Usable |
| ascii int32 |
|
Number of Rayleigh reference pulses usable. The pulse is usable if the laser transmitter frequency is locked; and Rayleigh reference pulse is not corrupted
|
|
| 6 | Num_Measurement_Invalid |
| ascii int32 |
|
Currently NOT used.
|
|
| 7 | Num_Reference_Pulse_Invalid |
| ascii int32 |
|
Currently NOT used.
|
|
| 8 | Num_Corrupt_Mie_Measurements |
| ascii int32 |
|
Total number of corrupt Mie measurements
|
|
| 9 | Num_Corrupt_Rayleigh_Measurements |
| ascii int32 |
|
Total number of corrupt Rayleigh measurements
|
|
| 10 | Num_Corrupt_Mie_Reference_Pulses |
| ascii int32 |
|
Total number of corrupt Mie reference pulses
|
|
| 11 | Num_Corrupt_Rayleigh_Reference_Pulses |
| ascii int32 |
|
Total number of corrupt Rayleigh reference pulses
|
|
|
|