Level_1A_Data_Quality_ADSR_04_04

binary record "Level_1A_Data_Quality_ADSR_04_04"size: 1114
idfield namedefinition
0start_of_observation_time
binary timesize: 12
Start time at start of BRC

unit: "s since 2000-01-01"

value: float(./days) * 86400 + float(./seconds) + float(./microseconds) / 1000000
binary recordsize: 12
ENVISAT binary datetime

idfield namedefinition
0days
binary int32size: 4
days since January 1st, 2000 (may be negative)

unit: "days since 2000-01-01"
1seconds
binary uint32size: 4
seconds since start of day

unit: "s"
2microseconds
binary uint32size: 4
microseconds since start of second

unit: "1e-6 s"
1observation_validity_indicator
binary uint8size: 1
TRUE = some critical BRC source packets invalid; FALSE = All critical BRC SP invalid
2measurement_validity_indicator
binary array[30]size: 480
binary recordsize: 16
Level 1A Measurement Validity Indicator

idfield namedefinition
0measurement_data_present
binary uint8size: 1
TRUE = Measurement data is present in BRC. FALSE = SID (measurement index + 4) missing
1mie_measurement_sp_valid
binary uint8size: 1
TRUE = Mie Measurement Source Packet Valid
2rayleigh_measurement_sp_valid
binary uint8size: 1
TRUE = Rayleigh Measurement Source Packet Valid
3measurement_valid
binary uint8size: 1
TRUE = if number of corresponding valid pulses is over Meas_Cavity_Lock_Status_Thresh (from processing parameters file); FALSE = otherwise
4spacecraft_attitude_on_target
binary uint8size: 1
TRUE = AOCS status indicates the spacecraft was in a stable state during any part of the measurement, as determined by AOCS status samples (SID1) falling within measurement interval
5velocity_of_attitude_uncertainty_error
binary doublesize: 8
Velocity of attitude uncertainty error

unit: "m/s"
6spare_1
binary bytessize: 3
Spare

hidden: true
3reference_pulse_validity_indicator
binary recordsize: 621
Reference Pulse Validity Indicator

idfield namedefinition
0mie_reference_pulses_present
binary uint8size: 1
TRUE = Mie Reference Pulses are present in BRC, FALSE=SID3 is missing
1rayleigh_reference_pulses_present
binary uint8size: 1
TRUE = Rayleigh Reference Pulses are present in BRC, FALSE=SID4 is missing
2mie_reference_pulse_sp_valid
binary uint8size: 1
TRUE = Mie Reference Pulse Source Packet Valid
3rayleigh_reference_pulse_sp_valid
binary uint8size: 1
TRUE = Rayleigh Reference Pulse Source Packet Valid
4pulse_validity_status_flag
binary array[600]size: 600
binary uint8size: 1
TRUE = Valid pulse status
5spare_2
binary bytessize: 17
Spare

hidden: true