Level_1B_Processing_IAT_Parameters_04_19

xml record "Level_1B_Processing_IAT_Parameters_04_19"
Processing parameters for Instrument Auto Test

idfield namedefinition
0File_Type
xml string
File type string
1Sph_Descriptor
xml string
ASCII string describing the product
2Lorentz_Refinement_Factor
ascii double
Lorentz refinement resolution ratio for creating the delta value of the estimate. (delta estimate = estimate / ratio) Given estimated value x, and refinement resolution r. Three adjacent points Lorentz(x), Lorentz(x+x/r), Lorentz(x-x/r) are computed for least squares fit. The refinement resolution r must be greater than 1.0
3Lorentz_Refinement_Threshold
ascii double
Lorentz refinement threshold. If ratio between delta(estimate) / estimate smaller than the threshold, stop the iteration and report the value
4Min_Num_of_Valid_Mie_Pulses
ascii int32
Minimum number of valid Mie pulses needed to generate valid output data for a frequency step
5Min_Num_of_Valid_Rayleigh_Pulses
ascii int32
Minimum number of valid Rayleigh pulses needed to generate valid output data for a frequency step
6Mid_Frequency_Range_Lower_Limit
ascii double
Lower frequency limit that defines the Mie fit range

attribute: unit
ascii stringsize: 3
fixed value: "GHz"
7Mid_Frequency_Range_Upper_Limit
ascii double
Upper frequency limit that defines the Mie fit range

attribute: unit
ascii stringsize: 3
fixed value: "GHz"