id | field name | definition |
0 | File_Type |
xml string |
File type string
|
|
1 | Sph_Descriptor |
xml string |
ASCII string describing the product
|
|
2 | Min_Num_of_Valid_Mie_Pulses |
ascii int32 |
Minimum number of valid Mie pulses needed to generate valid output data for a frequency step
|
|
3 | Min_Num_of_Valid_Rayleigh_Pulses |
ascii int32 |
Minimum number of valid Rayleigh pulses needed to generate valid output data for a frequency step
|
|
4 | Mid_Mie_Response_Pixel |
ascii double |
ACCD pixel position expected to be in the middle of the Mie USR
attribute: unit |
ascii string | size: 16 |
fixed value: "ACCD pixel index"
|
|
|
|
5 | Apply_Energy_Correction |
ascii uint8 |
Flag TRUE/FALSE to indicate if energy correction should be applied to Mie and Rayleigh.
mapping: "FALSE" -> 0
mapping: "False" -> 0
mapping: "false" -> 0
mapping: "TRUE" -> 1
mapping: "True" -> 1
mapping: "true" -> 1
|
|
6 | Energy_Drift_Correction_Factor_Mie |
ascii double |
The Energy_Drift_Correction_Factor_Mie describes a difference of the laser energy measured by PD74 and the actual signal level detected by the MSP ACCD.
|
|
7 | Energy_Drift_Correction_Factor_Channel_A |
ascii double |
The Energy_Drift_Correction_Factor_Channel_A describes a difference of the laser energy measured by PD74 and the actual signal level detected by the RSP ACCD for channel A. Such a difference might be caused by slightly different illumination angles of the different optical paths.
|
|
8 | Energy_Drift_Correction_Factor_Channel_B |
ascii double |
The Energy_Drift_Correction_Factor_Channel_B describes a difference of the laser energy measured by PD74 and the actual signal level detected by the RSP ACCD for channel B. Such a difference might be caused by slightly different illumination angles of the different optical paths.
|
|
9 | Num_Energy_Drift_Correction_Steps |
ascii uint32 |
Number of frequency steps
|
|