Specific_Product_Header_RBC_03_03

xml record "Specific_Product_Header_RBC_03_03"
Specific Product Header for ALD RBC products

idfield namedefinition
0Sph_Descriptor
xml string
SPH descriptor: ASCII string describing the product
1Spare_1
xml string

hidden: true
2Ref_RBC_Suite
xml string
Reference of the processing suite that was used to produce the Rayleigh Brillouin lookup tables
3Num_P
ascii uint16
Number of pressure bins in P_Grid
4Num_T
ascii uint16
Number of temperature bins in T_Grid
5Num_F
ascii uint16
Number of frequency bins in F_Gridtmp
6Num_FP
ascii uint16
Number of frequency bins in F_FP. This number is also the size of the arrays TA_FP and TB_FP
7Num_Fd
ascii uint16
Number of frequency bins in Fd
8Num_RR
ascii int16
Number of responses in RR
9Spare_2
xml string

hidden: true
10P_min
ascii uint32
Minimum pressure considered in the RBC calculations

unit: "Pa"

attribute: unit
ascii stringsize: 2
fixed value: "Pa"

available: optional
11P_max
ascii uint32
Maximum pressure considered in the RBC calculations

unit: "Pa"

attribute: unit
ascii stringsize: 2
fixed value: "Pa"

available: optional
12T_min
ascii uint16 (double)
Minimum temperature considered in the RBC calculations

unit: "1e-2 K"

converted unit: "K" (multiply by 1/100)

attribute: unit
ascii stringsize: 5
fixed value: "10-2K"

available: optional
13T_max
ascii uint16 (double)
Maximum temperature considered in the RBC calculations

unit: "1e-2 K"

converted unit: "K" (multiply by 1/100)

attribute: unit
ascii stringsize: 5
fixed value: "10-2K"

available: optional
14FSR
ascii double
Free spectral range of the Fabry-Perot interferometers. Copy of FSR specified in AUX_PAR_CS

unit: "GHz"

attribute: unit
ascii stringsize: 3
fixed value: "GHz"

available: optional
15USR
ascii uint16
Useful spectral range. Copy of USR specified in AUX_PAR_CS

unit: "MHz"

attribute: unit
ascii stringsize: 3
fixed value: "MHz"

available: optional
16df
ascii uint16
Frequency resolution. Copy of df specified in AUX_PAR_CS

unit: "MHz"

attribute: unit
ascii stringsize: 3
fixed value: "MHz"

available: optional
17Laser_Freq_Offset_Start
ascii double
First offset of the laser frequency in the Fabry-Perot transfer function file

unit: "MHz"

attribute: unit
ascii stringsize: 3
fixed value: "MHz"

available: optional
18Laser_Freq_Offset_Stop
ascii double
Last offset of the laser frequency in the Fabry-Perot transfer function file

unit: "MHz"

attribute: unit
ascii stringsize: 3
fixed value: "MHz"

available: optional
19Total_Num_of_Observations
ascii int32
Total number of observations used in the Fabry-Perot transfer function file
20Total_Num_of_Measurements
ascii int32
Total number of measurements used in the Fabry-Perot transfer function file
21Total_Num_of_Reference_Pulses
ascii int32
Total number of reference pulses used in the Fabry-Perot transfer function file
22Total_Num_of_Corrupt_Mie_Meas
ascii int32
Total number of corrupted Mie measurements in the Fabry-Perot transfer function file
23Total_Num_of_Corrupt_Ray_Meas
ascii int32
Total number of corrupted Rayleigh measurements in the Fabry-Perot transfer function file
24Total_Num_of_Corrupt_Mie_RefP
ascii int32
Total number of corrupted Mie reference pulses in the Fabry-Perot transfer function file
25Total_Num_of_Corrupt_Ray_RefP
ascii int32
Total number of corrupted Rayleigh reference pulses in the Fabry-Perot transfer function file
26Average_Error_FP_Response_A
ascii double
Average error in Fabry-Perot response in the transfer function file, for channel A
27Average_Error_FP_Response_B
ascii double
Average error in Fabry-Perot response in the transfer function file, for channel B
28Spare_3
xml string

hidden: true
29List_of_Dsds
xml record "List_of_Dsds"