id | field name | definition |
0 | num_points |
binary array[4] | size: 8 |
Number of points of the spectra
|
|
1 | num_fp |
binary uint16 | size: 2 |
Number of photometer output data per measurement
|
|
2 | num_satu |
binary uint16 | size: 2 |
Number of SATU output data per measurement
|
|
3 | fp_cen_wl |
binary array[2] | size: 4 |
Photometers central wavelength (photometer 1, followed by photometer 2)
binary uint16 (double) | size: 2 |
unit: "1e-1 nm"
converted unit: "nm" (multiply by 1/10)
|
|
|
4 | spec_eff_sampl_time |
binary float | size: 4 |
Spectrometer effective sampling time.
unit: "s"
|
|
5 | time_shift_rt |
binary float | size: 4 |
Effective time shift for ray tracing / geolocation
unit: "s"
|
|
6 | ref_wav_rt |
binary uint16 (double) | size: 2 |
Reference wavelength for the ray tracing
unit: "1e-1 nm"
converted unit: "nm" (multiply by 1/10)
|
|
7 | size_rad_sens_curve_limb |
binary uint8 | size: 1 |
Size of the radiometric sensitivity curve (limb)
|
|
8 | abs_rad_sens_curve_limb |
binary array[128] | size: 512 |
Abscissae of the radiometric sensitivity curve (limb)
binary uint32 (double) | size: 4 |
unit: "1e-3 nm"
converted unit: "nm" (multiply by 1/1000)
|
|
|
9 | rad_sens_curve_limb |
binary array[128] | size: 512 |
Radiometric sensitivity curve (limb) (unit: lf/e)
|
|
10 | size_rad_sens_curve_star |
binary uint8 | size: 1 |
Size of the radiometric sensitivity curve (star)
|
|
11 | abs_rad_sens_curve_star |
binary array[128] | size: 512 |
Abscissae of the radiometric sensitivity curve (star)
binary uint32 (double) | size: 4 |
unit: "1e-3 nm"
converted unit: "nm" (multiply by 1/1000)
|
|
|
12 | rad_sens_curve_star |
binary array[128] | size: 512 |
Radiometric sensitivity curve (star)
binary float | size: 4 |
unit: "photons/(s.cm2.nm.e)"
|
|
|
13 | temp_sp |
binary array[4] | size: 8 |
Thermistor temperature (SP), one for each CCD array
binary uint16 (double) | size: 2 |
unit: "1e-2 K"
converted unit: "K" (multiply by 1/100)
|
|
|
14 | temp_fp |
binary array[2] | size: 4 |
Thermistor temperature (FP), one for each photometer
binary uint16 (double) | size: 2 |
unit: "1e-2 K"
converted unit: "K" (multiply by 1/100)
|
|
|
15 | dark_charge |
binary array[3, 2336] | size: 14016 |
Dark charge used for the spectrometer dark charge correction
binary uint16 | size: 2 |
unit: "e"
|
|
|
16 | mean_spec_dark_charge |
binary array[4, 3] | size: 48 |
Mean spectrometer dark charge.
binary float | size: 4 |
unit: "e"
|
|
|
17 | mean_photo_dark_charge |
binary array[2] | size: 8 |
Mean photometer dark charge.
binary float | size: 4 |
unit: "e"
|
|
|
18 | therm_off |
binary array[6] | size: 12 |
Offset between thermistor and CCD arrays temperature 4 for Spectrometers then 2 for photometers.
binary uint16 (double) | size: 2 |
unit: "1e-2 K"
converted unit: "K" (multiply by 1/100)
|
|
|
19 | sun_coord |
binary array[3] | size: 12 |
Sun coordinates in the geocentric equatorial inertial system.
|
|
20 | spare_1 |
binary bytes | size: 16 |
Spare
|
hidden: true
|