id | field name | definition |
0 | dsr_time |
binary time | size: 12 |
Start time of the Data Set Record
unit: "s since 2000-01-01"
value: float(./days) * 86400 + float(./seconds) + float(./microseconds) / 1000000
binary record | size: 12 |
ENVISAT binary datetime
id | field name | definition |
0 | days |
binary int32 | size: 4 |
days since January 1st, 2000 (may be negative)
unit: "days since 2000-01-01"
|
|
1 | seconds |
binary uint32 | size: 4 |
seconds since start of day
unit: "s"
|
|
2 | microseconds |
binary uint32 | size: 4 |
microseconds since start of second
unit: "1e-6 s"
|
|
|
|
|
1 | quality_flag |
binary int8 | size: 1 |
Quality Indicator (-1 for blank MDSR, 0 otherwise)
|
|
2 | trans_spectra |
binary array[2336] | size: 9344 |
Full transmission spectra
binary float | size: 4 |
unit: ""
|
|
|
3 | cov |
binary array[2336] | size: 9344 |
Covariance function of the full transmission
binary float | size: 4 |
unit: ""
|
|
|
4 | scaled_back |
binary array[2336] | size: 4672 |
Scaled estimated central background
binary uint16 | size: 2 |
unit: "e"
|
|
|
5 | error_back |
binary array[2336] | size: 4672 |
Error bar for the estimated central background
binary uint16 (double) | size: 2 |
unit: "1e-1 %"
converted unit: "%" (multiply by 1/10)
|
|
|
6 | fp1_data |
binary array[500] | size: 2000 |
Photometers engineering data (FP1)
binary float | size: 4 |
unit: "e"
|
|
|
7 | fp2_data |
binary array[500] | size: 2000 |
Photometers engineering data (FP2)
binary float | size: 4 |
unit: "e"
|
|
|
8 | err_fp1 |
binary array[50] | size: 100 |
Error bar for the photometers engineering data (FP1)
binary uint16 (double) | size: 2 |
unit: "1e-1 %"
converted unit: "%" (multiply by 1/10)
|
|
|
9 | err_fp2 |
binary array[50] | size: 100 |
Error bar for the photometers engineering data (FP2)
binary uint16 (double) | size: 2 |
unit: "1e-1 %"
converted unit: "%" (multiply by 1/10)
|
|
|
10 | pcd_spec |
binary array[2336] | size: 4672 |
PCD at sample level (SP) for the spectrometers.
|
|
11 | pcd_fp |
binary array[2] | size: 4 |
PCD at sample level (FP) for the fast photometers. The first integer refers to photometer 1, the second to photometer 2.
|
|
12 | spare_1 |
binary bytes | size: 64 |
Spare
|
hidden: true
|