MIP_IG2_AX_MDSR_press

binary record "MIP_IG2_AX_MDSR_press"
idfield namedefinition
0dsr_time
binary timesize: 12
Time of creation

unit: "s since 2000-01-01"

value: float(./days) * 86400 + float(./seconds) + float(./microseconds) / 1000000
binary recordsize: 12
ENVISAT binary datetime

idfield namedefinition
0days
binary int32size: 4
days since January 1st, 2000 (may be negative)

unit: "days since 2000-01-01"
1seconds
binary uint32size: 4
seconds since start of day

unit: "s"
2microseconds
binary uint32size: 4
microseconds since start of second

unit: "1e-6 s"
1quality_flag
binary int8size: 1
Quality indicator (always set to zero)
2press_prof
binary array[dim_0]
Pressure profile

dim_0: int(/initial_guess_general_data[0]/num_elem)
binary floatsize: 4
unit: "hPa"